HA Ethernet Group Alarm
This alarm is applicable only to products supporting HA (Mediant 500, Mediant 800, Mediant 2600, Mediant 4000, Mediant 9000, and Mediant Software).
acHAEthernetGroupAlarm
Alarm |
acHAEthernetGroupAlarm |
||
---|---|---|---|
OID |
1.3.6.1.4.1.5003.9.10.1.21.2.0.137 |
||
Description |
The alarm is sent when the Ethernet link of at least one port in the Ethernet Group that is associated with the HA Maintenance interface is down. |
||
Default Severity |
Minor |
||
Source Varbind Text |
system#0 |
||
Event Type |
qualityOfServiceAlarm |
||
Probable Cause |
outOfService |
||
Severity |
Condition |
Text |
Corrective Action |
Minor |
At least one of the Ethernet port links in the Ethernet Group associated with the HA Maintenance interface is down |
"SYS_HA: Maintenance Group - One of the links is down - NO HA of maintenance link redundancy" |
Check that the Ethernet cables are connected securely to the ports. Check that the ports at the other end are up (working). |
Cleared |
All Ethernet ports in the Ethernet Group associated with the HA Maintenance interface become up again |
- |
- |