HA Ethernet Group Alarm

This alarm is applicable only to products supporting HA (Mediant 500, Mediant 800, Mediant 2600, Mediant 4000, Mediant 9000, and Mediant Software).

acHAEthernetGroupAlarm

Alarm

acHAEthernetGroupAlarm

OID

1.3.6.1.4.1.5003.9.10.1.21.2.0.137

Description

The alarm is sent when the Ethernet link of at least one port in the Ethernet Group that is associated with the HA Maintenance interface is down.

Default Severity

Minor

Source Varbind Text

system#0

Event Type

qualityOfServiceAlarm

Probable Cause

outOfService

Severity

Condition

Text

Corrective Action

Minor

At least one of the Ethernet port links in the Ethernet Group associated with the HA Maintenance interface is down

"SYS_HA: Maintenance Group - One of the links is down - NO HA of maintenance link redundancy"

Check that the Ethernet cables are connected securely to the ports. Check that the ports at the other end are up (working).

Cleared

All Ethernet ports in the Ethernet Group associated with the HA Maintenance interface become up again

-

-